Thermal energy metering
CACML - Multi-jet flow sensor suitable for heating purposes
MID MI001 APPROVAL
-
flow sensor suitable for heating purposes, multi-jet, dry dial, for temperature up to 130 °C;
- mod. CACML DN 15/20/25/32/40/50;
- MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.
WELC - Woltmann flow sensor suitable for heating purposes
MID MI004 APPROVAL
- flow sensor suitable for heating purposes, WOLTMANN helical vane, dry dial for temperature up to 130 °C;
- mod. WELC DN 50/65/80/100/125/150/200/250/300;
- MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.
UC - Electronic counter for thermal energy
MID MI001 APPROVAL
M-Bus wireless
OMS - Open Metering System
M-Bus
- model UC:
- remote electronic counter to connect to a mechanic, ultrasonic, electromagnetic meter installed over a return pipe; it is suitable to measure the thermal energy on heating and cooling systems;
- digital display with 8 digits plus special characters;
- powered by 10 years+1 lithium battery or optionally by 220V external supply or by M-Bus supply;
- optical communication with M-Bus protocol;
- data retrieve via single key on 3 (main/technical/stastics) levels installation on DIN rail, on plastic housing or wall mounting;
- 2 additional pulse input to manage 2 reed switch pulsed hot/cold sanitary water meters via internal terminal block with quick connections.
- model UCB:
- same features as model UC fitted with Mbus output with protocol according to standard EN 1434-3 and EN 13757-2;
- power suppy via M-Bus system with unlimited number of readings for each device.
- model UC2:
- with output for volume and energy;
- it is not possible to have M-Bus output and pulse inputs.
- model UCBR:
- with Wireless M-Bus interface;
- communication based on Opening Metering System standard (OMS), open system to ensure a common transmission standard among various meters (water, gas, heat, electricity);
- it is possible to change the default setting via a specific optical head setting software (as option).
- optional on all models:
- double recording for cooling/heating consumption.
- MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.
COMPACT2 - COMPACT2 DN 15 and DN 20
MID MI001 APPROVAL
M-Bus Wireless
OMS - Open Metering System
M-Bus
- Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
- Mid Directive 2014/32/EU, annex MI004
- Accuracy class EN 1434 Class 2
- Electromagnetic Class E1/Mechanical class M1
- lectronic Unit Protection Class IP65
- The meter is made of 03 main units: ultrasonic flow sensor, split electronic unit (85cm), pair of temperature sensors (1 inserted in the body, 1 loose)
- Bi-directional inductive detection (reverse flow) and air presence
- Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power
- Possible installation on delivery pipes through software configuration
- Available version for high temperature for district heating (130°max)
COMPACT2 - SONIK
MID MI001 APPROVAL
M-Bus Wireless
OMS - Open Metering System
M-Bus
- Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
- Mid Directive 2014/32/EU, annex MI004
- Accuracy class EN 1434 Class 3
- Electromagnetic Class E1/Mechanical class M1
- Electronic Unit Protection Class IP65
- The meter is made of 03 main units: single jet flow sensor, split electronic unit (50cm), pair of temperature sensors (1 inserted in the body, 1 loose)
- Bi-directional inductive uptake (reverse flow)
- Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power;
- Possible installation on delivery pipes through software configuration
- Possible software configuration (without approval) for use with glycols for type and percentage with energy value ≤10 kWh
SONIK HEAT - Thermal energy ultrasonic meter
MID MI001 APPROVAL
M-Bus wireless
OMS - Open Metering System
M-Bus
-
thermal energy ultrasonic meter, for temperature up to 130 °C;
- model SONIK HEAT THREADED DN 15/20/25/40;
- model SONIK HEAT FLANGED DN 25/40/50/65/80/100;
- MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434 (only heating version).
Heating accessories
- Pt temperature sensors, wet and dry mounting of sensor, OR gaskets, copper gaskets, bushings, brass mounts.
RSR - Electronic heat cost allocator
M-Bus wireless
OMS - Open Metering System
- electronic heat allocators in compact or remote sensor version for the distribution of heat consumption on radiators for central heating systems, or where it is not possible to use a metering system to correctly and fairly distribute heating costs of each individual flat;
- integrated W-MBUS interface in S1 or T1 mode(standard), 868Mhz frequency, according to DIN EN13757-4, AES128 encryption;
- optical interface for parameterization and reading of data via IR optical head and related software;
- the heat allocator in combination with a thermostatic or a chrono-thermostatic control head allows to implement a system for temperature control and consumption accounting;
- several kits available for installation on different types of existing radiators and convector heaters;
- approved according to HKVO, EN834 – Norm DIN EN834 (Nov.1994) DIN EN 13757-4.