Water meters, heat meters and radio remote reading systems, smart meters.
Wireless solutions IOT: radio applications.


G2 Colombia

 
  • VSF R1000.

    R1000 volumetric smart meter.

  • us

    Ultrasonic meter suitable for domestic and commercial outdoor applications, static measuring technology with no moving parts.
    Mod. US sizes DN 15 to DN 50 temperature class T30/T50, measuring range up to R500 Protection class: resin-coated IP68.

  • AFMS-PI.

    AFMS-PI.
    Super-Dry model temperature classes T30 and T50 (models up to R200 available on request).

  • RF-SLW.

    RF-SLW.
    AMR systems.

  • QDFM - PI.

    QDFM-, rollers protected, dry dial fully protected, measuring range R160 (models up to R315 on request), accuracy class 2, environmental class C, for turbid water.

  • Smart Meter

    UNI: protected rollers, FULLY PROTECTED DRY dial measuring range R315H-R160V, accuracy class 2, environmental class -25 +55°C, for turbid water.

Thermal energy metering

CACML - Multi-jet flow sensor suitable for heating purposes

CACML - Multi-jet flow sensor suitable for heating purposes

MID MI001 APPROVAL

MID MI001 APPROVAL

  • flow sensor suitable for heating purposes, multi-jet, dry dial, for temperature up to 130 °C;

  • mod. CACML DN 15/20/25/32/40/50;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

WELC - Woltmann flow sensor suitable for heating purposes

WELC - Woltmann flow sensor suitable for heating purposes

MID MI004 APPROVAL

MID MI004 APPROVAL

  • flow sensor suitable for heating purposes, WOLTMANN helical vane, dry dial for temperature up to 130 °C;
  • mod. WELC DN 50/65/80/100/125/150/200/250/300;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

UC - Electronic counter for thermal energy

UC - Electronic counter for thermal energy

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • model UC:
    • remote electronic counter to connect to a mechanic, ultrasonic, electromagnetic meter installed over a return pipe; it is suitable to measure the thermal energy on heating and cooling systems;
    • digital display with 8 digits plus special characters;
    • powered by 10 years+1 lithium battery or optionally by 220V external supply or by M-Bus supply;
    • optical communication with M-Bus protocol;
    • data retrieve via single key on 3 (main/technical/stastics) levels installation on DIN rail, on plastic housing or wall mounting;
    • 2 additional pulse input to manage 2 reed switch pulsed hot/cold sanitary water meters  via internal terminal block with quick connections.
  • model UCB:
    • same features as model UC fitted with Mbus output with  protocol according to standard EN 1434-3 and EN 13757-2;
    • power suppy via M-Bus system  with unlimited number of readings for each device.
  • model UC2:
    • with output for volume and energy;
    • it is not possible to have M-Bus output and pulse inputs.
  • model UCBR:
    • with Wireless M-Bus interface;
    • communication based on Opening Metering System standard (OMS), open system to ensure a common transmission standard among various meters (water, gas, heat, electricity);
    • it is possible to change the default setting via a specific  optical head setting software (as option).
  • optional on all models:
    • double recording for cooling/heating consumption.
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434.

COMPACT2 - COMPACT2 DN 15 and DN 20

COMPACT2 - COMPACT2 DN 15 and DN 20

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus Wireless

M-Bus Wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
  • Mid Directive 2014/32/EU, annex MI004
  • Accuracy class EN 1434 Class 2
  • Electromagnetic Class E1/Mechanical class M1
  • lectronic Unit Protection Class IP65
  • The meter is made of 03 main units: ultrasonic flow sensor, split electronic unit (85cm), pair of temperature sensors (1 inserted in the body, 1 loose)
  • Bi-directional inductive detection (reverse flow) and air presence
  • Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power
  • Possible installation on delivery pipes through software configuration
  • Available version for high temperature for district heating (130°max)

COMPACT2 - SONIK

COMPACT2 - SONIK

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus Wireless

M-Bus Wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • Compact electronic heatmeter, suitable for heat consumption measurements for central heating/cooling applications, and for hot water production sites
  • Mid Directive 2014/32/EU, annex MI004
  • Accuracy class EN 1434 Class 3
  • Electromagnetic Class E1/Mechanical class M1
  • Electronic Unit Protection Class IP65
  • The meter is made of 03 main units: single jet flow sensor, split electronic unit (50cm), pair of temperature sensors (1 inserted in the body, 1 loose)
  • Bi-directional inductive uptake (reverse flow)
  • Powered by 3V lithium battery (replaceable), estimated duration of 10 years depending on environmental/working conditions or preset for external electrical power;
  • Possible installation on delivery pipes through software configuration
  • Possible software configuration (without approval) for use with glycols for type and percentage with energy value ≤10 kWh

SONIK HEAT - Thermal energy ultrasonic meter

SONIK HEAT - Thermal energy ultrasonic meter

MID MI001 APPROVAL

MID MI001 APPROVAL

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

M-Bus

M-Bus

  • thermal energy ultrasonic meter, for temperature up to 130 °C;

  • model SONIK HEAT THREADED DN 15/20/25/40;
  • model SONIK HEAT FLANGED DN 25/40/50/65/80/100;
  • MI004 approved according to Directive 2004/22/CE MID, in compliance with the norms EN 1434 (only heating version).

Heating accessories

Heating accessories.
  • Pt temperature sensors, wet and dry mounting of sensor, OR gaskets, copper gaskets, bushings, brass mounts.

RSR - Electronic heat cost allocator

RSR - Electronic heat cost allocator RSR - Electronic heat cost allocator

M-Bus wireless

M-Bus wireless

OMS - Open Metering System

OMS - Open Metering System

  • electronic heat allocators in compact or remote sensor version for the distribution of heat consumption on radiators for central heating systems, or where it is not possible to use a metering system to correctly and fairly distribute heating costs of each individual flat;
  • integrated W-MBUS interface in S1 or T1 mode(standard), 868Mhz frequency, according to DIN EN13757-4, AES128 encryption;
  • optical interface for parameterization and reading of data via IR optical head and related software;
  • the heat allocator in combination with a thermostatic or a chrono-thermostatic control head allows to implement a system for temperature control and consumption accounting;
  • several kits available for installation on different types of existing radiators and convector heaters;
  • approved according to HKVO, EN834 – Norm DIN EN834 (Nov.1994) DIN EN 13757-4.
Remote reading for consumption measurement
Sistemi di lettura a distanza per contabilizzazione consumi

M-Bus Wireless

M-Bus wireless

 

OMS - Open Metering System

OMS - Open Metering System

 

M-Bus

M-Bus